Contact our customer service for a maximum 50% discount Contact our customer service for a maximum 50% discount
Contact us
Portable 2 IN 1 nd yag laser tattoo removal opt ipl laser hair removal machine Portable 2 IN 1 nd yag laser tattoo removal opt ipl laser hair removal machine Portable 2 IN 1 nd yag laser tattoo removal opt ipl laser hair removal machine Portable 2 IN 1 nd yag laser tattoo removal opt ipl laser hair removal machine Portable 2 IN 1 nd yag laser tattoo removal opt ipl laser hair removal machine Portable 2 IN 1 nd yag laser tattoo removal opt ipl laser hair removal machine

Product information

 

2 Handles Portable SHR IPL OPT permanent Hair Removal Device IPL epilation hair removal pigmentation vascular reduction

1.1 Overview

GM-220 is the first and only technology that combines IPL Super Hair removal technology. Gentle pulses of targeted energy isolate the treatment area and leave the surrounding skin free from potentially harmful side effects. In addition to permanent hair reduction for most hair colors and skin types, Two Opt effectively and comfortably treats rosacea, spider veins; skin imperfections caused by sun damage, age spots, enlarged pores and uneven skin tones. A series of Two Opt treatments will leave your skin smoother clearer with a tighter more youthful appearance.

1.2 Device Brief Introduction

Product name: Two OPT Treatment System  Super HR super hair removal machine

1.4 Medical Use-Application Areas

1. Permanent hair removal

2. Skin rejuvenation

3. Reduction of pigmented lesions

4. Wrinkle removal

5. Acne Therapy

6. Freckle, vascular lesions and facial blemish removal

2.1.2 Control Panel

Operation of this device is done through the control panel. It includes the following parts:

Key switch: Used to turn on and off the power supply. (Clockwise to turn on and counter clockwise to turn off)

Emergency turn off switch: The red button found in the front panel of the device is used to immediately shut off the device’s power supply in case of any emergency. Pressing this button will cut off the power supply to the whole system. Rotating the button in the direction of the arrow printed on its surface will disengage the button and will reengage the power supply. When this button is engaged, remember to turn the key switch to the off position afterwards.

The Liquid Crystal Display (LCD) shows the operational settings and adjustments as well as system status is displayed on the screen.

2.1.3 The Two Opt treatment handpiece

The Two Opt handle consists of a (1) Cable housing: this contains the power cable, liquid coolant tubing, control data cable; (2) Opt head:  this houses the control switch, flash lamp, sapphire crystal, filter piece and electronic semi-conductor cooling system.  

Pressing on the trigger on the Two Opt treatment head discharges the flash lamp at the settings as displayed on the control panel. Pushing down the foot switch like-wise discharges the device (on selected models only). The supplied sapphire crystal measures 12mm x 35 mm and is superior in both clarity and longetivity, thereby increasing both the efficiency of the flash lamp and lifespan of the treatment head. It is very important to keep the sapphire crystal clean. Make sure to clean this with a soft cloth after each treatment. A disinfectant such as alcohol can be used between treatments. Dried gel on the crystal filter will reduce efficiency of the flash lamp. Replace the plastic guard over the filter to prevent damage. In the event that the sapphire crystal is damaged (i.e. nicked or cracked) contact your dealer immediately.

2.2 Accessories:

Key /1pcs   

Protection glasses (operator) /1pair             

Protection goggles (patient) /1pair

Drainage hose /1pc                          

Funnel/1pc

Power cable /1pc                           

2.2.2 Protection Glasses

One pair of protective glasses is provided with the device. The opaque glasses are to be worn by the patient and the filtered 430-1200 nm glasses are to be worn by the operator. Despite wearing the protective glasses, avoid staring directly into the intense pulses of light during the treatment. Only personnel wearing protective glasses may be allowed to observe the treatment.

2.2.3 Light-coupling Gel

The light-coupling gel is used to maximize the conduction of light from the flash lamp to the skin. The light-coupling gel must be clear/transparent and not colored/tinted. Colored gels absorb light therefore reducing the effectiveness of the treatment. The light-coupling gel must be chilled but not frozen. Frozen gel diffuses the light emitted by the flash lamp reducing its efficacy. Light-coupling gels must be non-alcohol based. The Two Opt produces considerable heat; flammable material must be kept clear of the treatment area.

Please order the light-coupling gel in the local market.

  • Product information

 

2 Handles Portable SHR IPL OPT permanent Hair Removal Device IPL epilation hair removal pigmentation vascular reduction

1.1 Overview

GM-220 is the first and only technology that combines IPL Super Hair removal technology. Gentle pulses of targeted energy isolate the treatment area and leave the surrounding skin free from potentially harmful side effects. In addition to permanent hair reduction for most hair colors and skin types, Two Opt effectively and comfortably treats rosacea, spider veins; skin imperfections caused by sun damage, age spots, enlarged pores and uneven skin tones. A series of Two Opt treatments will leave your skin smoother clearer with a tighter more youthful appearance.

1.2 Device Brief Introduction

Product name: Two OPT Treatment System  Super HR super hair removal machine

1.4 Medical Use-Application Areas

1. Permanent hair removal

2. Skin rejuvenation

3. Reduction of pigmented lesions

4. Wrinkle removal

5. Acne Therapy

6. Freckle, vascular lesions and facial blemish removal

2.1.2 Control Panel

Operation of this device is done through the control panel. It includes the following parts:

Key switch: Used to turn on and off the power supply. (Clockwise to turn on and counter clockwise to turn off)

Emergency turn off switch: The red button found in the front panel of the device is used to immediately shut off the device’s power supply in case of any emergency. Pressing this button will cut off the power supply to the whole system. Rotating the button in the direction of the arrow printed on its surface will disengage the button and will reengage the power supply. When this button is engaged, remember to turn the key switch to the off position afterwards.

The Liquid Crystal Display (LCD) shows the operational settings and adjustments as well as system status is displayed on the screen.

2.1.3 The Two Opt treatment handpiece

The Two Opt handle consists of a (1) Cable housing: this contains the power cable, liquid coolant tubing, control data cable; (2) Opt head:  this houses the control switch, flash lamp, sapphire crystal, filter piece and electronic semi-conductor cooling system.  

Pressing on the trigger on the Two Opt treatment head discharges the flash lamp at the settings as displayed on the control panel. Pushing down the foot switch like-wise discharges the device (on selected models only). The supplied sapphire crystal measures 12mm x 35 mm and is superior in both clarity and longetivity, thereby increasing both the efficiency of the flash lamp and lifespan of the treatment head. It is very important to keep the sapphire crystal clean. Make sure to clean this with a soft cloth after each treatment. A disinfectant such as alcohol can be used between treatments. Dried gel on the crystal filter will reduce efficiency of the flash lamp. Replace the plastic guard over the filter to prevent damage. In the event that the sapphire crystal is damaged (i.e. nicked or cracked) contact your dealer immediately.

2.2 Accessories:

Key /1pcs   

Protection glasses (operator) /1pair             

Protection goggles (patient) /1pair

Drainage hose /1pc                          

Funnel/1pc

Power cable /1pc                           

2.2.2 Protection Glasses

One pair of protective glasses is provided with the device. The opaque glasses are to be worn by the patient and the filtered 430-1200 nm glasses are to be worn by the operator. Despite wearing the protective glasses, avoid staring directly into the intense pulses of light during the treatment. Only personnel wearing protective glasses may be allowed to observe the treatment.

2.2.3 Light-coupling Gel

The light-coupling gel is used to maximize the conduction of light from the flash lamp to the skin. The light-coupling gel must be clear/transparent and not colored/tinted. Colored gels absorb light therefore reducing the effectiveness of the treatment. The light-coupling gel must be chilled but not frozen. Frozen gel diffuses the light emitted by the flash lamp reducing its efficacy. Light-coupling gels must be non-alcohol based. The Two Opt produces considerable heat; flammable material must be kept clear of the treatment area.

Please order the light-coupling gel in the local market.